CHAPTER 5 SWITCH SETTING 5.1
Introduction
The three switch blocks and
three jumpers on the PCCOM 8 port adapter must be configured correctly
in accordance with the operating system you are using.
SW1 (Switch 1) SW2 (Switch 2) SW3 (Switch 3) JP1 (Jumper 1) JP2 (Jumper 2) All addresses specified are in
hexadecimal. The actual interrupt latch address is set to the interrupt
vector address set by switch 3 + 2H.
|
¡@5.2 Selection of Switch SettingsIt is important to refer to the
user manual supplied with your operating system to determine the
correct configuration. Although we provide installation advice for
various operating systems, it is not possible to cover all systems in
this user guide. Please contact your supplier if you have any
difficulties with configuration.
IMPORTANT
: CARE MUST BE TAKEN IN SELECTING THE CONFIGURATION OF SWITCHS
TO ENSURE YOU DO NOT DUPLICATE SETTINGS OF OTHER EQUIPMENT ALREADY
INSTALLED IN YOUR COMPUTER. DUPLICATION OF SETTINGS WILL RESULT IN A
MALFUNCTION OF ONE OR BOTH DEVICES.
Please refer to the following
settings for each switch block. If you are installing more than one
board, do not duplicate jumper settings for any parameter.
|
DECISION COMPUTER INTERNATIONAL CO .,LTD. ¡@ DECISION
INTERNATIONAL CO.,LTD. ¡@ ¡@
NOTE:
The address selected must start on a multiple of 40H. A block of 40H
contiguous I/O locations will be used starting from the selected
address.
The I/O port
addresses corresponding to each port are shown in the following. |
|
JP1:
Select
master or slave
Suppose you used one
common interrupt to serve 24 ports, it must select one board as master
board that generates interrupt, and the other two boards as slave. It
shows how to connect daisy chain interrupt in the following.
NOTE THAT, WHEN THE DAISY CHAIN FUNCTION IS USED, ONLY SET INTERRUPT (SWITCH 2) ON MASTER BOARD, DO NOT SET IRQ ON SLAVE BOARD.