APPENDIX C XENIX/UNIX CONFIGURATION The distribution diskette
contains SCO, AT&T, UNIXWARE, and INTERACTIVE UNIX/XENIX driver, it
detects non-FIFO or FIFO chips automatically. Our drivers also provide
transparent printer features that let user to connect local printer
from auxiliary port of terminal. The hardware configuration and
software installation procedures are shown is the bellows.
C.1 Suggested Hardware Configuration 1. First adapter I/O port address: 2A0H, 2A8H Interrupt level: IRQ3 or IRQ5 or IRQ10
2. Second Adapter I/O port address: 1A0H, 1A8H
Interrupt level: IRQ4 or IRQ12 C.2 Software Installation The installation procedure for the device drivers is described as follows:
#cd /
# doscp d:dc.tz ./dc.tar.Z ["dosget" in Interactive UNIX] # zcat dc.tar / tar xvfp -
#cd
/usr/sys/pccom/dc
# ./install
#
entty ttyj11
# entty ttyj12 . . For SCO UNIX & XENIX by using
enable command.
NOTE:
:unix.old
a. login as a
root user
b. # cd /usr/sys/pccom/dc c. Remove PCCOM Driver from the kernel #./ remove
#distty ttyj11
C.3 Option for High Speed The configuration of High-Speed Baud Rate card is change as follows: C.4 Transparent Printer The default device names to
Transparent Printer(TP) are /dev/lpXYY, that is, the prefix name is
changed from "tty" to "lp" but the other "XYY" is the same. e.g. under
default device names, the corresponding TTY line of /dev/lpj11 is
/dev/ttyj11.
By multiplexing a serial line,
there are two sorts of data channels for TTY data(by /dev/ttyXYY) and
TP data(by /dev/lpXYY). If the /dev/ttyj11 is used for a TTY, it has to
be enabled before you would like to print data through /dev/lpj11 to a
printer that connected to the terminal that is operated via /dev/ttyj11.
The channel for TP data that is
uni-directional is used to transmit the data from a host to a terminal
only. The differentiates of TTY data and TP data in the same serial
line is that TP data are encapsulated within a couple of PRINT-ON and
PRINT-OFF escape strings that are recognized by connected terminals.
The PRINT-ON and PRINT-OFF is defined by connected terminals.
The scheme to multiplex a
serial line for these two channels is based on time-division method.
The time slices for TTY or TP data are generated according to the entry
procedure, polling, in the PCCOM driver, which is periodically called
by system clock. The period of system clocks is different among various
operating systems, e.g. most UNIXs is 100hz, but SCO Xenix is 50hz.
The interval reserved for TTY
or TP channel in the same serial line is important to output TP data to
a low-speed printer through high-throughput line from PCCOM cards if
there is no flow control XON/XOFF to the serial line.
The lpx command is used to
adjust the time interval for TTY or TP data and the TP protocol.
lpx [option]
device name
-t
number:
set interval for TTY
-l number: set interval for Transparent Printer -n string: set esc string to turn on printer -f string: set esc string to turn off printer -T : get interval for TTY -L : get interval for Transparent Printer -N : get esc_string to turn on printer -F : get esc_string to turn off printer
The range of interval reserved
for TTY or TP channel is from 1 to maximum integer. The default setting
for any /dev/lpXYY is as follows:
Interval for TTY : 50
Interval for TP : 1 PRINT - ON escape : ¡§\033[5i¡¨ (ESC[5i) PRINT ¡V OFF escape : ¡§\033[4i¡¨ (ECS[4i) The examples to invoke lpx
# lpx -t 60
/dev/ttyj11
# lpx ¡V12
/dev/lpj11
# lpx ¡VL
/dev/lpj11
# lpx ¡Vn
¡§\033[51¡¨ /dev/lpj11
# lpx ¡VF
/dev/lpj11 \033[4i
|
||||||||||||||||||||||||||||||||||